12-268 Modifications
Original section ↗ · Link to this section
- (1) When the residential code refers to the "chief appointed authority" or the "chief administrator," it shall be deemed to be a reference to the city manager.
- (2) The adopted code is modified and amended as follows:
- (a) Section R313, automatic fire sprinkler systems, is not mandatory, pursuant to T.C.A. § 68-120-101(a) (8).
- (b) Chapters 34--43, relating to electrical installations, are deleted and the National Electrical Code, 2017 edition, shall apply.
- (c) Figure R301.2(2), seismic design categories, is deleted and replaced with Figure R301.2(2), seismic design categories site Class D, from the 2015 IRC.
- (d) Section N1102.4.1.2 (R402.4.1.2), testing, is replaced with section N1102.4.2.1, testing option, and section N1102.4.2.2, visual inspection, from the 2009 IRC.
- (e) Section N1103.3.3 (R403.3.3), duct testing (mandatory), and section N1103.3.4 (R403.3.4), duct leakage (prescriptive), are optional.
- (f) Table N1102.1.2 (R402.1.2), insulation and fenestration requirements by component, and Table N1102.1.4 (R402.1.4), equivalent U-factor, from 2018 IRC, are replaced with Table N1102.1, insulation and fenestration requirements by component, and Table N1102.1.2, equivalent U-factor, from 2009 IRC.
- (g) Section N1102.4.4 (R402.4.4) when the fenestration U-factor of 0.50 or lower is used, a skylight U-factor of 0.65 or lower is used, a glazed fenestration SHGC of 0.30 or lower is used, a 90 AFUE furnace is used, an 85 AFUE boiler is used, and a 9.0 HSPF heat pump (heating) and 15 SEER (cooling) are used.
- (h) Table N1102.1, insulation and fenestration requirements by component, in the 2009 edition, is adopted and amended by adding the following as footnote "M": "Log walls complying with ICC400 and with a minimum average wall thickness of five inches or greater shall be permitted in Zone 4 when a fenestration U-factor of 0.35 or lower is used, a skylight U-factor of 0.60 or lower is used, a 90 AFUE furnace is used, an 85 AFUE boiler is used, and a 9.0 HSPF heat pump (heating) and 15 SEER (cooling) are used."
- (i) Section 313.1, townhouse automatic sprinkler system, is amended by adding, "However, an automatic sprinkler system shall not be required in a three-unit townhouse with less than 5,000 gross square feet and three or fewer stories if each unit is separated by a two-hour firewall."