= 4. The primary mechanical equipment would be replaced and the existing ductwork would be reused and modified if needed for any room reconfiguration. 5. The primary electrical panels would be replaced and additional receptacles would be located as needed. The panel would be sized to accommodate any new addition. The existing lighting would be replaced with new LED lighting throughout the renovated spaces. Emergency lighting needs will be addressed to accommodate the current code requirements. 6. Plumbing fixtures would be replaced to accommodate ADA accessibility and sensor technology. 7. The sidewalk area at the front entrance will need to be reconfigured to accommodate ADA accessibility. The public and private restrooms will have to be renovated to accommodate ADA accessibility. Egress and approach to the renovated areas will have to be renovated to ensure proper access. 8. Site, landscaping, utilities, and parking will need to be reconfigured to accommodate any building addition. To accommodate the programmatic needs of the city two floor plans were developed to study layout, adjacencies and cost. Scheme 1 is a single-story addition that would expand the existing building on the south side by approximately 3,700 sf. This would require removing the existing park lot and any associated utilities to accommodate the building addition. This location will allow the building to be structural separated and also allow the addition to be constructed with minimal disruption to the existing facility. The new addition would house the new community space/court room and allow for a dedicated exterior entrance to help with security and access currently lacking in the existing facility. Other spaces include offices, restrooms, and a new main conference room. As these spaces are relocated from the main building, renovations can be done to update finishes, MEP items, ADA updates, and minor space reconfiguration. The approximate cost associated with this scheme ranges from $2,000,000 to $2,100,000, Scheme 2 is a 2nd story addition over the existing 1 si story structure. While this design does minimize additional site usage it does require significant structural modifications. The 5,200 sf 2nd story addition would require an elevator and stairs to meet the required egress and ADA 35