2022 08 16 City Council
City Council · packet · 137 pages · Descriptive metadata inferred from filename
Extracted text for page 99
Unverified text extraction. Check the original page for numbers, names, and layout.
INTAKE VETTING 143 INTAKE 147 VEST. 101 KITTEN 104 OFFICE 105 CAT 106 CL. 107 CORR. 108 VEST. 111 RECPT. 109 CAFE 127 MOM & PUP 118 BITERS 117 ELEC / MECH 116 MEET & GREET 124 CONF. 128 LAUNDRY 123 FOOD PREP 125 SAN. SUP. 126 OFFICE 145 I.T. 129 OFFICE 130 ELEC. / STOR. 141 TLT. 140 KENNEL #3 138 GENERAL HOLDING 120 OPEN OFFICE 102 OFFICE 134 OFFICE 135 OFFICE 136 RISER 137 OFFICE 131 CORR. 146 EUTH. 139 MEN 115 WOMEN 114 VEST. 112 KENNEL #2 121 36' - 8 1/2" ± 15' - 3 3/4" ± 80' - 11 3/4" ± 8' - 10" ±113' - 4" ± 42' - 6 3/4" ± 4 3/4" 20' - 2" 4' - 0" 10" 21' - 4" 4' - 11" 10' - 4" 4' - 11" 19' - 2 1/2" 4 3/4" 8' - 3" 14' - 3 1/4" 12' - 11" 7' - 10 3/4" 4 3/4" 10' - 5"4 3/4"7' - 10 1/2" A2.1 1 A2.1 2 5' - 0" 4' - 4" 4 3/4" 10' - 4" 4 3/4" 4 3/4"12' - 6" 4 3/4" 5' - 11" 11' - 8 1/4" 4 3/4" 8' - 10 1/2" 12' - 10 1/2" 9' - 0 1/2" 13' - 7 1/4" 4 3/4" 5' - 0" 91' - 4 3/4" 26' - 4" 1' - 2" NEW METAL PICKET FENCE - SEE CIVIL DWGS. EXIST. METAL CANOPY EXIST. METAL CANOPY NEW 4" REINF. CONC. WALK NEW METAL PICKET FENCE - SEE CIVIL DWGS. SEE CIVIL DW GS. FOR CONTI NUATION OF FENCED PATH TO DOG RUN EXISTING LOADING DOCK EXIST. OVERHEAD SECTIONAL DOOR 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 8' - 8" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 8' - 7" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 2 1/4"5' - 2 1/4" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 3' - 4 3/4"5' - 0" 5' - 0" EXIST. CONC. STEPS & LANDING 63' - 4" ± 6' - 0" 10' - 4" 5' - 0" 5' - 7 1/2" 21' - 4" 4' - 2" 5' - 8" 21' - 4"6' - 3" 4 3/4" 27' - 2" 52' - 4" ± 132' - 11 3/4" ± CL. 103 KENNEL #1 122 OFFICE 132 ALTERNATE 1 UNDER BASE BID THIS AREA IS TO REMAIN "AS IS" EXCEPT FOR THE INSTALLATION OF NEW FIRE SUPPRESSION SYSTEM AND AS OTHERWISE NOTED AND/OR AS MAY BE REQUIRED TO PERFORM THE WORK OF THE BASE BID. IF ALTERNATE #1 IS NOT INCLUDED IN THE CONTRACT, EXISTING CONSTRUCTION AND FINISHES THAT MUST BE DISTURBED TO ACCOMPLISH BASE BID WORK SHALL BE DONE AS MINIMALLY AND ORDERLY AS POSSIBLE, AND WILL NOT BE REQUIRED TO BE REPAIRED, EXCEPT ANY STRUCTURES DISTURBED (e.g. FLOOR SLAB, WALLS, ETC.) SHALL BE REPAIRED TO A PLUMB, LEVEL, AND FINISHED CONDITION (CONCRETE TROWEL SMOOTH) SUITABLE TO BE LEFT EXPOSED. SEE SHEET A1.3 FOR ALTERNATE #1 WORK. A2.3 1 A2.2 1 1 A7.1 A9.1 1 A11.1 3 A11.1 1 2 4 A11.15 A11.17 6 A11.2 2 LOBBY 110 CORR. 113 FLOOR PLAN GENERAL NOTES 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION BETWEEN SUBCONTRACTORS BASED ON THE ENTIRE SET OF DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A BIDDER OR SUPPLIER WHO HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS, THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. 2. DO NOT SCALE DRAWINGS. USE PRINTED DIMENSIONS ONLY. 3. ALL DIMENSIONS ARE TO FINISH FACE OF WALL AND OPENING UNLESS NOTED OTHERWISE. 4. CEMENT BACKER BOARD SHALL BE SUBSTITUTED FOR GYPSUM BOARD WHERE CERAMIC TILE IS SCHEDULED, EXCEPT AT RATED PARTITIONS. 5. RUN GYPSUM BOARD 6" ABOVE ADJACENT CEILING SYSTEM UNLESS REQUIRED TO GO TO DECK. 6. STAGGER OUTLETS AND OTHER OPENINGS THAT PENETRATE WALLS. (MIN 12") 7. CAULK ALL JOINTS WHERE DISSIMILAR MATERIALS MEET. 8. IT IS THE INTENT OF THIS CONTRACT THAT ALL INTERIOR WALLS BE FINISHED AND PAINTED TO A UNIFORM APPEARANCE. 9. ALL NEW INTERIOR WALLS TO BE PAINTED. COLOR TO BE SELECTED BY ARCHITECT AND APPROVED BY OWNER. 10. AT ALL DRYWALL PARTITIONS, PROVIDE CONTROL JOINTS @ 20'-0" O.C. MAX. OR AS NOTED. PROVIDE JOINT REINFORCEMENT. CONTROL JOINTS TO BE PAINTED TO MATCH WALL. 11. PROVIDE BLOCKING AT ALL WALL HUNG CABINETS, MIRRORS, WALL-MOUNTED TOILET ACCESSORIES, TOILET PARTITIONS, DRINKING FOUNTAINS, TELEVISIONS, ETC. IF LOCATED IN STUD WALLS. 12. DOORS TO BE 4" FROM INTERIOR GYPSUM WALL CORNER UNLESS OTHERWISE NOTED. 13. DOORS TO BE 4" FROM INTERIOR CMU WALL CORNER UNLESS OTHERWISE NOTED. 14. REFER TO ENLARGED FLOOR PLAN SHEETS CONTAINING MORE DETAILED DIMENSIONS AND INFORMATION. 15. EVERY DOOR TO HAVE 18" CLEARANCE ON PULL SIDE OF DOOR. DOORS WITH CLOSER TO HAVE 12" CLEARANCE ON PUSH SIDE. 16. REFER TO LIFE SAFETY PLAN FOR LOCATIONS OF FIRE EXTINGUISHERS 17. SLOPE FLOORS TO FLOOR DRAINS AS INDICATED. 18. E.J. = EXPANSION JOINT. SEE FLOOR FINISH PLANS FOR DETAILS 19. IT IS THE RESPONSIBILITY OF THE G.C. TO FIELD VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. 20. ALL DOORS NOT TAGGED ARE EXISTING DOORS TO REMAIN. Allen&Hoshall engineers • architects • surveyors Allen & Hoshall 1661 International Drive, Suite 100 Memphis, TN 38120 901 820 0820 fax 901 683 1001 NOT FOR CONSTRUCTION CHECKED: DRAWN: JOB NO: DATE: COPYRIGHT Allen & Hoshall This document is proprietary to Allen & Hoshall and shall not be reproduced or used by others without prior written consent. F:\63006-4- Athens Muni Fac Reno- TO #5- Animal Shelter\REVIT\63006 - ARCH CENTRAL ANIMAL SHELTER R20.rvt 8/5/2022 2:58:53 PM A1.2 DIMENSION FLOOR PLAN - BASE BID CITY OF ATHENS TENNESSEE CITY OF ATHENS ANIMAL SHELTER MHL NS 05/20/22 63006 100% Owner Review 320 S Jackson Street Athens, Tennessee 37303 1/8" = 1'-0"1 DIMENSION FLOOR PLAN -BASE BID No. Description Date 96